PRODUCT

Product Introduction
Application and functions
MGG/KL-CC model insertion type electromagnetic flow sensor and
MGG/KL-CC model insertion type electromagnetic flow converter mated to be MGG/KL-CC model insertion type electromagnetic flow meter to measure the volume flow of kinds of conductive liquids.
Characters of sensor:
A) Without moving parts in the sensors, simple structure and reliable working;
B) It could be installed and dismounted in the condition of non-stopped fluid, so it is very convenient to be used to measure pipe flow and easy to maintain and repair.
C) Accuracy will not be influenced by medium temperature, pressure, density, viscosity and conductivity(more than 5μs/cm) etc.
D) There is nearly no any pressure lost and energy consumption is very lower.
E) Manufacturing and installation costs will be lower, especially used to large size and middle size pipes.
F) Using advanced low frequency square wave excitation. Zero point will be more stable, strong resist-interference performance and reliable running.
G) Wide flow range; the full scale of fluid velocity could be any set from 1m/s to 10m/s, output signal and flow will be linear relation.
H) Not only 0~10mA/DC or 4~20mA/DC standard current output, but also 1~5kHz frequency output, that is why it will be widely used to chemical, fiber, metallurgy, fertilizer, paper pulp, water supply and drainage, sewage treatment and irrigation industries.
Structure
Insertion type electromagnetic flow meter will be installed by base, ball-valve, gland nut and positioning screw. Tube type sensor is suitable to measure flow of clean mediums, but flat electrodes type sensor is suitable to measure flow of some mediums with impurities.
Main technical performance
(a). Suitable nominal diameter of pipes:
DN32~3000mm;
(b). Flow velocity:
0~1m/s to 0~10m/s,full scale could be adjusted during 1~10m/s.
(c). Accuracy:
±1.0% when full scale velocity >1m/s.
(d). Conductivity:
>50μs/cm;
(d). Working pressure:
1.6Mpa。
(e). Electrodes materials:
SUS316L, HB, HC, Ti, Tan, Stainless steel coated with tungsten carbide.
(f). Material of measuring head:
ABS
(g). Max medium temperature:
ABS 60℃
(h). Protection grade:
IP68
(i). Output signal
0.2mVp-p/0.2mVp-p/
(j). Max transfer distance from sensor to converter is 50m(please contact with us if any special requirement)
(k). Output signal of flow meter:
DC:0~10mA loading resistance is 0~1kΩ;
4~20mA loading resistance is 0~500Ω;
Frequency:1~5KHz loading resistance is 250~1.2kΩ.
Key words:
01 MGG/KL-CC
Related Products
Related Products
Message